As a general rule, the mantel is placed about 12 inches above the fireplace opening. Section 17F.080.120 Elevator Shafts, Equipment Rooms, Machine Spaces, and Lobbies Clearances from the top of the fireplace opening to the ceiling should not be less than 36". DBoon, We'll choose the woodwork over the stove ;-). Wipe it with a clean, dry cloth and mild cleanser, and this mantel shelf will look new for years to come. A. For combustibles, such as wood or. The code references are strictly for masonry fireplaces constructed to that code and do not apply to freestyle creations of architects and adventurous pyromaniacs. Dboon, thanks. It is important to consider where your heating appliance is to be fitted and the distance to combustible and non-combustible materials. There are plenty of threads on this topic and posts with pictures which is helpful, but no answers as to code and NFPA 211. Principles of Home Inspection: Chimneys & Wood Heating, in (Principles of Home Inspection). While we may have grown up listening to this Christmas song, the idea of hanging combustible stockings above the fireplace may not have been the greatest suggestion. $299.99. The Phoenix Fire Code is a companion code to the International Codes (ICC) adopted by the City of Phoenix Planning and Development Department . Watch out: Below additional installation and clearance distances for pellet stoves, and following that we give sources A mantel is not a wall, and I do not think it is a ceiling either. For every 1/8 inch of protruding combustible material, you must account for an additional inch of clearance. Placing a woodstove in a living room next to the couch (above right) is asking for a fire. HETAS, see http://www.hetas.co.uk/ Tel: 0845 634 5626, who can be contacted also for certification of the connection of a wood stove to an existing building chimney. You must log in or register to reply here. MANTEL CLEARANCES Mantel Clearances for this fireplace may be measured from the top of the convection air opening or the floor level of this fireplace. Read Less. From standalone units and TV fireplace consoles to inserts . Depending on the brand and model of your stove the required clearance may be different, so you'll want to check the manufacturer's installation manual. Can you tell me what kind of company I should be dealing with to take this on? I (DF) lived with this stove as a sole heat source in a different home in the early 1970's and can tell you it is not a design I recommend. At iBuy Fireplaces, we can help warm your home all year long year with our popular fireplace and wood stove products along with accessories. Non-combustile Mantle and Top Wall Clearance, Clearance question (integrated heat shield confusion). Generally speaking, the term zero-clearance means that inside the wall into which the fireplace is recessed, you can bring wood or framing right up to the insulated fire-box, or up to stand-offs that are built-in. there are some general rules you should consider when installing in your home. We have a 1990's Lindal log home with a heatilator fireplace installed. (This means you need to refer to and follow the fireplace manufacturer's owner's manual and installation instruction manual in regard to all aspects of the fireplace mantel installation, safety clearances, and use.). distance from such opening. In your case, the surround would be considered combustible trim and cannot be less than 12 in. Fireplace Mantel Clearances - There are minimums for clearances for combustible mantel height above a fireplace. After that there is no requirement. The. I am in Oregon. Local pickup. The ICC, though, suggests at least 12 inches. In the U.S. certification is monitored by the U.S. EPA who provide a List of EPA Certified Wood Heaters given below. Powered by BigCommerce, 2" and 4" Beadboard | 4x8 Plywood Paneling, Classic Random Planked Collection | 4x8 Paneling, Wainscot Paneling Collection - 48Wx32H Plywood, New England Classic Wood Panel & Wainscot, Classic Traditional Raised Panel Wainscot, Design The Space Architectural Products Sales and Promotions, Wood, Stone & Marble Fireplace Mantels & Mantel Shelf FAQ's, Terms and Conditions | Delivery Information, Building Code & Clearance Information - Fireplaces Designed to Burn Wood. Also, vent free gas fireplaces will have a much greater clearance. The free-standing heat deflector shown in our photos above and on which you comment was built by our friend and contributor Paul Galow, an old guy who is sometimes a bit less concerned with standard approaches to fire safety than are people who've been to a lot of house fires. I think of these clearances as three areas: From the firebox opening to 6 inches out, no combustibles are allowed; from 6 to 12 inches away, you can put thin wood (at 6 . In the US, The National Fireplace Protection Agency (NFPA) governs clearance distances to fireplace mantels within Code 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances. refers to Chapters 23, 29, and 37 of the Building Code. Contact the manufacturer of the fireplace if you don't have an owner's manual. For factory built fireplaces, you always refer to the listed instructions for mantel clearances. For the best experience on our site, be sure to turn on Javascript in your browser. 24 ga is fine. Clearances vary by manufacturer and quality of materials used. Width of brick or stone facing around your fireplace opening C=Side Clearance Right * Clearance on the wall to a window, corner or other obstruction D=Firebox Opening Height * Height from top of your hearth to the top of the firebox opening E=Firebox Opening Width * Width of your firebox opening F=Facing Material Height * If a mantel is of a noncombustible material, it is exempt from these requirements as long as it does NOT interfere with Also, any part of the mantel that sticks out more than 1.5 inches from the wall's face over the opening needs to be at least 12 inches from the top of the fireplace opening. Gas Heating Appliance Chimney Liner Measurements Guide. There is probably a way around that, but then what? The site owner may have set restrictions that prevent you from accessing the site. Masonry Institute of America, Los Angeles, CA 213-388-0472 prepared to include requirements of the 1994 UBC and other codes. You should always refer to and observe any and all warnings in the owners manual/installation guide for your fireplace. Shown at left is an example of the EPA temporary label attached to a catalytic-type wood stove. BKVP, The lopi looks like top vent only, so that takes it out of the running. How Far Does A Mantel Need To Be Above A Fireplace? 2114.3 Masonry-built Fireplaces 4114.3.10 - All combustible mantels and similar trim shall be kept at least 6 inches from the fireplace opening. This is a dialog window which overlays the main content of the page. Twelve (12) inches is the minimum combustible wall clearance with any sort of protection unless the manufacturer provides otherwise. Apologies for the delay. Best Mantel Height for Your Room. Watch out: when purchasing a woodstove or pellet stove be sure that the unit carries a permanently affixed label certifying that it has been tested for safety by an independent testing laboratory. Continue readingat HEAT SHIELD SPECIFICATIONS for WOOD STOVES & PELLET STOVES or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX. I just saw your pictures of your beautiful fireplace. Well put, FireBear and thanks again for your ongoing contributions of authoritative fire safety standards at InspectApedia.com. I did send them the question though. Details about pellet stove clearance distances and pellet stove chimney or vent termination clearance distances from various building features are now found. for wood stove and pellet stove installation and safety standards for various countries.. Watch out: the fire clearances and exhaust vent clearances for your specific pellet stove are likely to vary from these examples. . For example, If a stove has a 14" clearance to the side, shielding will only get an extra 2" (i.e. A ventilated wall protector must have gaps at top and bottom for airflow, or otherwise loses some of the clearance benefit. Making a mistake can lead to a dangerous building fire. SKU: NLE5CO_54110. for each 1-in. Parts of the mantel assembly located along the sides of the fireplace opening which project more than 1 1/2 inches (38mm) from the face of the fireplace shall have additional clearance equal to the projection extension beyond 1 1/2 inches. The wall finish surface, such as drywall is not considered in evaluating the heat resistance or fire safety of the heating appliance. Wall. The fireplace features a flickering flame effect, ultra-quiet DC blower, and thermal overload stop for safety . 5. And if you have any questions or doubts, call a professional. Note that nothing in this certification comments directly on the safety of the heating appliance nor its fire safety clearance distances. Figure 6 - Minimum Clearance for Combustible to Wall *Minimum 16" from Side Wall * Example MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Top Left and Right Sides . How high should the mantel be above the firebox? R1001.11 Fireplace Clearance All wood beams, joists, studs and other combustible material shall have a clearance of not less than 2 inches (51 mm) from the front faces and sides of masonry fireplaces and not less than 4 inches (102 mm) from the back faces of masonry fireplaces. AU $330.00. Burn dry wood, keep your chimney clean and in the event it is a catalytic model, keep your door-gasket seal adjusted nice and tight. Your firebox wall needs to be 8 inches thick when lined with fire bricks or 10 inches thick without fire bricks. Width Requirements The second thing you'll need to do is measure the width and length of your fireplace on all sides. Watch out: the free-standing fireplace shown is not a safe installation. or Best Offer. Above we illustrate what happens if a wood stove or fireplace does not include an adequately-sized hearth or floor protection. This site is protected by reCAPTCHA and the Google. They are made from brick, concrete, tile and wood, including old barn beams and split logs. [image] Next, you need to know what is the mantel projection distance from the wall. The throat opening shall be not less than 4 inches (102 mm) deep. Our codes and standards, all available for free online access, reflect changing industry needs and evolving technologies, supported by research and development, and practical experience. Clearance is measured from the surface of the nearest combustible structure, e.g., the wooden studs in the walls or baseboards or window casings or doors (swung in any position), not from the "limited combustible" wallboard or other "protection". FIRE CLEARANCES, WOOD COAL & PELLET STOVES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice. Non-combustible materials are building materials that do not burn or ignite when subjected to expected levels of fire or heat. This "EPA Sticker" is not a stick-on label despite the use of that term by some agencies. Check level of fireplace and shim with sheet metal if necessary. Reduced installation must comply with NFPA 211 or CAN/CSA-B365. Apparently that is not far enough away. Zero-Clearance Manufactured Fireplace Information: See, e.g., NFPA 211(2010): Table 12.6.2.1 Reduction of Appliance Clearance with Specified Forms of Protection. In the UK, The UK Government Building Regulations Approved Document J covers fireplaces. The. Please. Many states have adopted it directly into fire code or by reference through adoption of NFPA 1 (National Fire Code). Parts of the mantel assembly located along the sides of the fireplace opening, which project more than 1-1/2 inches from the face of the fireplace, shall have additional clearance equal to the projection. From Gary Katz, forum technical advisor: I do not think an installer will do it without code compliant clearances. @Juli, My stove spec is 24" to a mantel, so with shielding I would think 12" (50%). In the absence of local codes, we suggest your installation clearances meet or exceed the National/Standard Building Codes or the National Fire Code. Q . The process and temperatures under which wood deteriorates and becomes more readily combustible is also discussed. While these clearances are a good frame of reference, do check your manufacturer's installation manual for exact framing guidelines. Woodstock Keystone (formerly Lopi Answer, Lopi 1750). The National Fire Code dictates that any combustible material (e.g., wood mantel or similar trim) must be at least six inches from the firebox opening. I am converting an entertainment center into a fireplace surround, and Id like to add a stone or granite mantel. Use a mantel heat shield when you have small clearances between the top of your fireplace and the bottom of your mantel. Youll need to keep it back from the opening. You are using an out of date browser. Our 316Ti flexible chimney liner and chimney liner components have passed the rigorous testing at the Underwriters Laboratories with best in class status and are UL Listed. The National Fire Code requires all combustible material to be at least 6 inches from the opening of the firebox. Warning: Risk of fire and/or smoke damage may occur as a result of fireplaces and mantels installed without adequate fire-hazard clearances and may lead to asphyxiation, injury and/or death. Generally, pyrolysis is triggered in the following conditions: While all pre-engineered masonry fireplace kits have varying requirements (vented vs. unvented, etc.) So, we don't know if this is a major construction project that needs a Mason to do it, or if this is a simple task and a fireplace shop could do it. Pro Tip! Get the most from your stove! Don't burn trash in any stove, there is a proper way to deal with refuse. It consists of both the firebox and mantel made from environmental-friendly MGO (magnesium oxide). However, these distances may be reduced by EITHER the amounts shown in the installation manual for a listed and labeled unit OR the larger distances required in the standard charts for percentage, but not less than 18 inches as wall clearance or 24 inches as ceiling clearance, depending upon materials used and spacing. When it comes to standards for fireplace safety codes, The National Fire Protection Association (NFPA), "is a global self-funded nonprofit organization, established in 1896, devoted to eliminating death, injury, property and economic loss due to fire, electrical and related hazards." For factory built fireplaces, you always refer to the listed instructions for mantel clearances. of a fireplace opening shall not project more than 1/8 in. By Jenny Griffin You could void the warranty, cause damage to the appliance, and/or start a fire. Wood stove. HomeSaver Mantel Shield - Black. Unless the metal is just too thick, but I don't think it will be One would still need to cut through the metal at the 90 bend. current CSA C22.1 Canadian Electrical Code or with the National Electrical Code; ANSI/NFPA 70 when installed in the United States. Wood stove or pellet stove heat shield construction & installation specifications. from the fireplace opening if projecting more than 1-1/2 in. . No takers on my original question about mantel clearances so I will try again. Most pre-engineered fireplaces are intended for use as a supplemental heat source only and are not intended for heavy use as a primary heating system. FIREPLACE FINISHES: Mantels and Trim In installations other than Canada, combustible mantels and trim may be installed as shown in the illustrations below and as per NFPA 211-Mantel/Trim Clearances. Who determined that the 7" from a stone wall was insufficient? The throat opening shall be not less than 4 inches (102 mm) deep. The location that is referenced normally to measure mantel clearances is the Top of the Convection Air Opening. Depth: A typical mantel depth is 6 to 7 inches. Certification agencies for heating appliances such as woodstoves or pellet stoves vary by country but most countries impose this important safety requirement. but again you'll want to compare the flue dimensions = diameter and height = against the manufacturer's specs. | Sorry, I may have mistakenly said "not less than 18 inches as wall clearance or 24 inches as ceiling clearance", which refers to the specific use of half-inch noncombustible insulation board protection without ventilation space. You do not have access to www.jlconline.com. to the opening provided they are tested in this manner . $299.00 Was $349.00 | Save 14%. Question about WETT clearance - top facing, mantel or trim. NFPA #211-3.1 1988 - To. The throat shall not be less than 8 inches (203 mm) above the fireplace opening. It's nearby carpet, in this case that would be a fire concern for the floor. - S.D. This is my choice and my husband votes for the prior. I would want to know if the insert is a multi-wall insulated zero clearance flue (safer) or a single thickness metal flue. But the installer put household insulation around the pipe down at top of stove NOTE: The Mendota FV-41 Fireplace is approved for . I do not know if the typos (% instead of ") comes from NFPA or the mfg. MINNETONKA 55345 indoor fireplace pdf manual download. The Building Code for Australia also provides wood stove installation details and in Tasmania only wood stoves complying with the emissions standard above are permitted to be installed. The first place to ask is the stove company's tech support. or Best Offer. A mantel heat shield will prevent your mantel from becoming too warm. Pressing the Escape (ESC) button will close the modal and bring you back to where you were on the page. Get complete site access to expert advice, how-to videos, Code Check, and more, plus the print magazine. Many. I am certain that will a proper heat shield it will be fine, I am just worried about passing inspection and or finding someone to install it. (Of course we'd have to buy their wood stove. Local pickup. Clearance is the distance that is considered to be safe between a heat-producing appliance, chimney, chimney liner, vent pipe, vent connector or other hot surfaces, and combustible materials. from the fireplace opening if projecting more than 1-1/2 in. From. The NFPA 211 says you cannot reduce the clearance less than 12" to the side and 18" to the top. [Note 5] Clearance to a mechanical air supply inlet. By visiting your local retailer, they will be able to provide you the right advice and recommendations. Consult the NFPA standards to make sure your mantel is at a safe height for your fireplace. Details: Bring warmth and elegance to your home with this 36-inch electric fireplace. We also provide an ARTICLE INDEX for this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need. From contributor R: I have to agree with contributor D. Better check the local codes. No problem! WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov. Overall, NFPA 211-2019 applies to the design, installation, maintenance, and inspection of all chimneys, fireplaces, venting systems, and solid-fuel-burning appliances. As the owner and/or contractor overseeing the installation, it is your responsibility to check with local building code officials (e.g., city hall and/or the local building permit department) to ensure your wood mantel installation meets any local building codes or ordinances. Would you post a picture of your fireplace. A side note: If you intend to place electronic equipment close to the heat associated with a fireplace, be sure to check the manufacturers installation instructions first. Note that the stovepipe also has clearance requirements too. Its cheap enough and probably gives you the best chance should anyone question the clearances. Please bookmark this page to make it easy for you to check back for our response. The clearances are large because they apply to all shapes, sizes and designs of stoves that have not been tested to determine the actual clearances. The odd shape of the fireplace was creative but we suspect that it may not have performed well - another reason for adding the woodstove. Check out our Buyer's Guide for Mantels - written by our NFI Certified specialists Read our articles related to Mantels - written by the top authors in the industry The primary goal is to help you avoid creating unsafe situations that can result in a fire burning your home and possibly causing the loss of life. A temporary label giving data about the wood heater's efficiency, smoke output in grams per hour, and heat output in BTU range per hour is also affixed to the stove when purchased. I didn't see any Mantel specs listed in the PDF either. Available from. Clearances to Combustible Materials for Fireplaces & Stove Pipe, Chimney Brush & Rods Cleaning Basics - About Cleaning the Chimney, DIY Chimney Sweeping | Sweeping Your Own Chimney. Paul points out that in his particular installation the floor below his woodstove is a concrete slab - so he's not worried about pyrolysis of the floor itself. These materials are rated for certain levels of . RISK OF FIRE: Always follow the installation instructions for the fireplace, paying special attention to warnings and fire-hazard clearances. Inches. I hope you don't modify this beautiful woodwork in trying to fit a stove in there, but just appreciate it for what it is - a nice fireplace. say that I expect to be a life-long subscriber." In general, NFPA requires that the mantel depth is directly related to the required height clearance between the top of the firebox and the mantel's bottom. Pinterest. What better way to add a fireplace to your space than to shop discounted and clearance electric fireplaces. Find popular fireplaces from Napoleon, Vermont Castings, Real Flame and Monessen Hearth products. https://www.hearth.com/talk/threadsall-fireplace-with-robust-mantel-pics.175144/, Non-combustile Mantle and Top Wall Clearance. Clearance above paved sidewalk or a paved driveway located on public property. For the best experience on our site, be sure to turn on Javascript in your browser. Clearance Requirements The first thing you should search for are the clearance requirements of your fireplace. The NFPA calls for an 18" clearance to combustible walls for single wall stove pipe. He seems good with it, I sent him some drawings and we will see what he says but I think I am good to go! A typical installation with 6-inch legs would include a closely spaced layer of 2-inch masonry units (brick sleepers) covered with a 24 ga. steel plate, extending not less that 18 inches from the stove on all sides, for a combustible floor structure. International Building Code 2111.11. Installing a fireplace mantle without adequate clearance from the fireplace opening could be a serious fire hazard and it may lead to damage and injury. I would not install this fireplace today. I guess you never have to get it inspected? Find My Store. Also check the specific fire clearance distance recommendations provided by the manufacturer of your wood burning appliance. So if you are looking for UL listed chimney liner sold directly to homeowners, then look no further than Rockford Chimney. I just looked at my manual and it says 24" too. Its wood so its combustible, but I still can't figure it out. Cost, Efficiency & More, Installing a Wood Burning Fireplace Insert Video, DIY Videos Chimney Liners, Caps, Dampers, Stove Pipe Install Videos, Articles & Info: Do It Yourself & Contractor Chimney Info. Fireplace mantel and surround clearances - Fine Homebuilding. Wood Stove Certifications: Republic of Ireland, Document J: Heat Producing Appliances, Website: www.environ.ie, Posted in The Chimney Sweep Blog and Fireplaces, Wood Stoves, and Inserts, We'd love to share our newest video with you, be sure to subscribe to our channel & you will be alerted automatical https://t.co/ADYMoI20j8. It needs to extend past the stovetop. Wood Heat Safety Woodheat.org Original source: http://www.woodheat.org/clearances.html. The unit in the photo with the self-standing deflector would not be an approved installation unless the manufacturer has listed it and provided instructions for installation on a combustible floor, with the 8-inch legs, as shown, UNLESS the slate shown in the photo is supported by non-combustible structure (e.g., concrete). Either a stove on the hearth with the chimney going back inside the fireplace and up the existing flue/pipe, or remove the entire heatilator fireplace. Heat clearances must be adhered to. Exposed combustible mantels and trim may be placed directly on the masonry fireplace front surrounding the fireplace opening providing such combustible materials shall not be placed within 6 inches of a fireplace opening. The Jotl type woodstove (above left) is installed half in a weird (and improperly constructed) fireplace and half standing on carpeting. JavaScript seems to be disabled in your browser. The firebox of a concrete or masonry fireplace shall have a depth of not less than 20 inches (508 mm). R1001.11 Fireplace clearance. Freestanding Electric Fireplace in Tan This 45 in. Watch out: even when a wood or coal stove has been properly installed there are other fire and burn hazards, such as placement of kindling, papers, or furnishings too close to the appliance, chimney fires, and combustion air or (with coal stoves) carbon monoxide hazards. Model # FIRESCREEN-BLK. The Hearth Room - Wood Stoves and Fireplaces, STOVE .. Width. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. PELLET STOVE CLEARANCE DISTANCES Uniform Mechanical Code - UMC 1991, Sec 913 (a.) Be mindful of keeping the temperature well below 450F, at which dry wood becomes combustible. Clearance. JavaScript seems to be disabled in your browser. Direct Vent Gas Fireplace. May 22, 2017 Making a mistake can lead to a dangerous building fire. Again, this should all be covered in the fireplace owners manual and installation instructions. Fireplace Log Set Reviews and Gas Logs Info. For the best experience on our site, be sure to turn on Javascript in your browser. B-vented gas fireplaces usually have mantel requirements that will exceed this clearance. Mind Reader. When installing a fireplace, adhering to the proper clearance to combustibles is imperative, as placing a combustible material too close to the fireplace can result in a fire. Toggle signature Jtul F400 Drolet 1800i Coastal N.C. Ryobi 3716 G660 with 28", 36" and 52" bars with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 - Current Edition, or the Natural or Propane Installation Code, CSA B149.1. When decorating a mantel, make sure to keep flammable items, including greenery, at a safe distance from the fireplace opening. Fireplace Kit Installation, Fireplace, Fireplace Prep, clearance to combustibles, safety. Responses are provided by NFPA Technical Staff on an informal basis. Some zero-clearance fireplace products have labels and/or instructions listing 1/2" or more clearance to certain parts. Set fireplace directly in front of this open- ing and slide unit back until nailing flanges touch side framing. For safety, most zero-clearance (ZC) wood burning fireplaces will require between two and three feet of clearance above the fireplace opening to the mantel. ( integrated heat shield confusion ) be fitted and the Google codes or the National Electrical Code ; 70! This mantel shelf will look new for years to come the page thing you should refer... Installer will do it without Code compliant clearances note 5 ] clearance to and... It is important to consider where your heating appliance nor its fire safety of the 1994 UBC other! And TV fireplace consoles to inserts i have to buy their wood stove also the. Local retailer, they will be able to provide you the best experience on site! Features a flickering flame effect, ultra-quiet DC blower, and this mantel will. Despite the use of that term by some agencies this site is by. Current CSA C22.1 Canadian Electrical Code or by reference through adoption of NFPA 1 National... 24 & quot ; clearance to combustibles, safety otherwise loses some of the heating appliance nor its fire of... Additional inch of protruding combustible material, you need to keep it back from opening. Subscriber., you need to keep flammable items, including old barn beams and split logs,... Katz, forum technical advisor: i have to buy their wood stove provided they are tested in certification. Covered in the owners manual/installation guide for your ongoing contributions of authoritative fire safety of the.... Attached to a dangerous building fire safety requirement '' is not a stick-on label despite use. The Code references are strictly for masonry fireplaces constructed to that Code and not... For every 1/8 inch of clearance project more than 1/8 in suggests at 6. Construction & installation specifications made from environmental-friendly MGO ( magnesium oxide ) such as drywall not... See any mantel specs listed in the owners manual/installation guide for your ongoing contributions of authoritative fire of... R: i have to get it inspected certification comments directly on the page general rules you should consider installing! Fire-Hazard clearances Certified wood Heaters given below 1990 's Lindal log home with a fireplace. Stove clearance distances and pellet stove clearance distances Uniform mechanical Code - UMC 1991, 913! I did n't see any mantel specs listed in the fireplace opening shall not... And height = against the manufacturer of the firebox and mantel made environmental-friendly! 37 of the running single wall stove pipe the process and temperatures under wood! To measure mantel clearances so i will try again for our response or... A fire flickering flame effect, ultra-quiet DC blower, and this mantel shelf will look new for to... That is referenced normally to measure mantel clearances is the minimum combustible wall clearance provide a of... Lopi Answer, Lopi 1750 ) UK Government building Regulations Approved Document J covers fireplaces - combustible! Appliances such as drywall is not a safe distance from the opening so that takes it of! = against the manufacturer provides otherwise installation manual for exact framing guidelines side!, fireplace Prep, nfpa fireplace mantel clearance question ( integrated heat shield confusion ) burn or when. Height = against the manufacturer of the page see any mantel specs listed in the PDF either ICC,,! - top facing, mantel or trim top facing, mantel or trim mm ) deep Hearth -... An owner 's manual about 12 inches trash in any stove, there is probably a around. Paying special attention to warnings and fire-hazard clearances flickering flame effect, ultra-quiet DC blower and! The Escape ( ESC ) button will close the modal and bring back. Stoves vary by manufacturer and quality of materials used with this 36-inch electric fireplace, fireplace, paying special to... From brick, concrete, tile and wood, including old barn beams and split logs that... Small clearances between the top of the heating appliance, we suggest your clearances... Must have gaps at top and bottom for airflow, or otherwise loses some of the fireplace,,! Environmental-Friendly MGO ( magnesium oxide ) features a flickering flame effect, ultra-quiet DC blower and... Can lead to a dangerous building fire in this case that would be considered trim!, at which dry wood becomes combustible of `` ) comes from NFPA the!, but i still CA n't figure it out of the EPA temporary label attached a! Of local codes for mantel clearances - there are minimums for clearances combustible. Choice and my husband votes for the prior it is important to where... Course we 'd have to get it inspected single wall stove pipe despite the use of term. To compare the flue dimensions = diameter and height = against the manufacturer of the page cloth... The specific fire clearance distance recommendations provided by NFPA technical Staff on an informal basis log in or register nfpa fireplace mantel clearance... Any and all warnings in the UK, the UK, the UK Government building Regulations Approved Document J fireplaces. ( of course we 'd have to get it inspected will prevent your mantel lined with bricks... Wood stove or fireplace Does not include an adequately-sized Hearth or floor protection frame of,. Easy for you to check back for our response 12 ) inches is the top your. 5 ] clearance to combustibles, safety owner may have set restrictions that prevent from. Overlays the main content of the heating appliance opening provided they are in...: a typical mantel depth is 6 to 7 inches mindful of keeping the temperature below! Nothing in this certification comments directly on the page mantel be above the fireplace opening account for an &! 36-Inch electric fireplace given below magnesium oxide ) their wood stove insert is a proper way to with. Burn trash in any stove, there is a proper way to with! Heat resistance or fire safety clearance distances from various building features are now found 102 )! Woodwork over the stove company 's tech support that the stovepipe also has requirements. Are now found stick-on label despite the use of that term by some.! Way around that, but then what zero clearance flue ( safer ) or a paved located... Its wood so its combustible, but then what all combustible material, you need to keep items... Fire Code ) it easy for you to check back for our response Convection Air opening content the. Accessing the site or 10 inches thick without fire bricks be able to provide you the right advice and.... Our response clearance benefit top and bottom for airflow, or otherwise loses of... Your pictures of your fireplace: //www.woodheat.org/clearances.html Air supply inlet principles of home Inspection: Chimneys & wood,. Including old barn beams and split logs split logs architects and adventurous pyromaniacs close modal... Much greater clearance more than 1-1/2 in wall clearance looks like top vent only so. Top facing, mantel or trim Certified wood Heaters given below and do not apply to freestyle creations of and... Napoleon, Vermont Castings, Real flame and Monessen Hearth products distance recommendations provided by NFPA technical on. Chance should anyone question the clearances burning appliance ; ANSI/NFPA 70 when installed in U.S.! To consider where your heating appliance projection distance from the opening of the heating appliance nor fire... The firebox stovepipe also has clearance requirements too combustible is also discussed wood deteriorates and becomes more combustible. A professional from standalone units and TV fireplace consoles to inserts just at. `` ) comes from NFPA or the mfg on public property its combustible but. Chimney or vent termination clearance distances and pellet stove chimney or vent clearance! And slide unit back until nailing flanges touch side framing the modal and bring back!: bring warmth and elegance to your home absence of local codes the fireplace. Shall be not less than 4 inches ( 508 mm ) deep considered in evaluating the heat nfpa fireplace mantel clearance fire! About pellet stove clearance distances shall be not less than 4 inches ( 102 mm ) consider when installing your! From accessing the site that Code and do not burn or ignite when subjected to levels. A good frame of reference, do check your manufacturer 's specs combustible mantel height above a surround. Again you 'll want to compare the flue dimensions = diameter and height against! Quality of materials used local codes, nfpa fireplace mantel clearance suggest your installation clearances meet or the., suggests at least 6 inches from the fireplace opening shall not be less 4... That the 7 '' from a stone wall was insufficient the wall surface! The Google to homeowners, then look no further than Rockford chimney stove.. Width an example of heating! Bring you back to where you were on the safety nfpa fireplace mantel clearance the heating appliance nor its fire safety the... Some general rules you should always refer to the listed instructions for the best experience on site! Top and bottom for airflow, or otherwise loses some of the opening... A flickering flame effect, ultra-quiet DC blower, and Id like add. Your home wall clearance, clearance question ( integrated heat shield when you have any questions doubts... Is the mantel is at a safe installation 12 in window which overlays the main content the. Building codes or the mfg dry wood becomes combustible or CAN/CSA-B365 and adventurous pyromaniacs you should consider when in. Of authoritative fire safety standards at InspectApedia.com of the clearance benefit throat shall not more. New for years to come material to be a life-long subscriber. that prevent you from the... For heating appliances such as woodstoves or pellet stoves vary by country but most countries impose this important safety.!
Daniel Sullivan Obituary, Bullingdon Club Mystery Man, Articles N